Scanbody Implant
video

Scanbody Implant

Production Introduction scan body we made is compatible more than 30 different systems, and friendly-use, easy to be scanned, and easy to be library-matched with EXO/ 3 Shape. scanbody implant work length is minimum 6mm working height. And the material is Titanium Grade 5 for medical. The...
Send Inquiry

Description

Technical Parameters

Production Introduction

 

scan body implant we made is compatible more than 30 different systems, and friendly-use, easy to be scanned, and easy to be library-matched with EXO/ 3 Shape.  

 

scan body implant work length is minimum 6mm working height. And the material is Titanium Grade 5 for medical.

 

The scan body is generally a digital device used in dentistry to capture three-dimensional impressions of a patient's mouth. Through its software, the teeth are recreated with a precision that far exceeds the traditional ones with a mold, and this helps us in many different treatments.

 

Main features and benefits:

1. Original Raw Material: titanium alloy

2. High accuracy guarantee

3. Body made of metal, it provides an ideal surface for optical scanning

4. The Torque Wrench is required to adjust Chirimen Benchtop Scan Bodies. Features a torque control mechanism that ensures proper torque setting

 

Belows are the tipical systems we usually use:  

System

Specs

Scanbody No.

Osstem TS

3.5

OSC-OST-TS35

4.5

OSC-OST-TS45

Dentium

4.5

OSC-DT-SL45

Straumann Bone Level

3.3(NC)

OSC-ITI-BNL33

4.1(RC)

OSC-ITI-BNL41

Straumann Synocta

4.8(RN)

OSC-ITI-SYN48

6.5(WN)

OSC-ITI-SYN65

Nobel Active

3.5(NP)

OSC-NB-ACT35

4.3(RP)

OSC-NB-ACT43

Nobel Replace

3.5(NP)

OSC-NB-RP35

4.3(RP)

OSC-NB-RP43

5.0(WP)

OSC-NB-RP50

Zimmer Tapered Screw-vent

3.5

0SC-ZM-TSV35

4.5

OSC-ZM-TSV45

5.7

OSC-ZM-TSV57

ZimmerAzure AC

3.5

OSC-ZM-AC35

4.5

OSC-ZM-AC45

 

INSTRUCTIONS

1.Product Description 

The Scanbody implant is a device used to establish the virtual 3D position of the implant in relation to the oral cavity. It is made up of three elements: titanium base, body and titanium insertion screw.

 

2.Intended use 

The Scanbody sits directly on the implant connection or on an element transepithelial, depending on the model, serving as a reference during the process of intraoral CAD/CAM scanning, or in the laboratory, to later carry out the design and machining of prosthetic restorations.

 

3.Indications 

The purpose of use is to facilitate the transmission of information between the clinic and the laboratory in relation to prosthetic restorations on implants, through the incorporation of digital technology. This will allow the processing of the scanned images and the subsequent design and manufacture of structures and accessories in the laboratory, through specific software, improving precision and reproducibility in the manufacture of prostheses on the implant.

 

4.Procedure

Carry out the following checks:

✓ Compatibility with the corresponding implant or transepithelial element

✓ Cleaning and disinfection

✓ Sterilization and subsequent cooling at a temperature of 20-40ºC ✓ Check perfect condition and assembled

✓ Permanence in the mouth less than 60 minutes

✓ Perfect condition of the implant to be connected

✓ Scan

✓ Scanbody removal

 

5.Contraindications 

Allergy and hypersensitivity to the chemical components of the materials used, titanium alloys.

 

6.Side effects and interactions 

It is recommended to follow the instructions for use recommended by the manufacturer. an improper use of the product may lead to harm to the patient such as infections and/or swallowing of the product or an incorrect scan result.

 

7.Cleaning, disinfection and sterilization

Upon detection of any packaging defect, the product should not be used, and should be contact the manufacturer. All ScanBodies are supplied clean and conveniently packaged. The scanbody is sold non-sterile. Before use, the professional must carry out the cleaning and sterilization. Chirimen recommends always carrying out a previous cleaning with products used in the sector dental, relying on ultrasonic baths or automatic methods of cleaning and disinfection and then proceed to sterilization. Before sterilizing, products must be transferred from their original container to another suitable for such effect. Sterilization must be carried out in a wet steam autoclave at 121ºC for 15 minutes. or 134ºC at a minimum of 3 minutes, according to UNE-EN-ISO 17665-1:2007, in bags or boxes of sterilization. Do not use the product after sterilization if any damage to the packaging is observed. It must be taken into account that materials can suffer wear throughout their life cycle, Therefore, Chirimen recommends a maximum of 20 sterilizations per element, within which the quality characteristics of the product are preserved.

 

8.Warnings

Before use, it must be checked that the material is in perfect condition and there are no damaged parts. disassembled, to prevent aspiration or swallowing of part or all of the components. In addition, it is highly recommended to check that the product is clean and disinfected and that the patient connection area is clean and free of debris. Scanbody references can only be used with compatible digital libraries. The professional using the reference product should have experience in using this product. product safely and in accordance with the instructions for use provided by Chirimen, being the responsibility of the same professional the application of said element to the patient needs.

 

9.Precautions 

Chirimen recommends not using the product after a maximum of 20 sterilizations, with its corresponding cleaning and disinfection, for the guaranteed maintenance of your functions. It should be especially noted that each reference must be used in combination with elements that are dimensionally compatible and that are indicated on the product label itself

 

10.Compatibility 

Chirimen's Scanbody family references are available for various implant sizes duly indicated on the label of each reference and on the company catalog.

 

11.Additional information

Consult the instructions for use of the scanner to be used Consult the instructions for use of Chirimen databases

 

12.Validity 

These instructions for use correspond to the current version of the references of the family of Scanbody products indicated at the foot of the document.

 

13.Storage 

Chirimen’s products do not require special storage conditions, although they are recommends not exposing them to conditions that may affect both the product and the packaging or labeling of it, such as extreme temperature and humidity, shock, etc.


Product Pictures 

 


scan body is compatible with system below:

 

different system

 

Certification 

certifications

 


Dental CAD/CAM System Workflow:

Dental CADCAM System Workflow

 

Packing & Delivery

transportation andpackage 

 

 

Company Profile

 


Exhibition Photos

exhibition 


 


Hot Tags: Scanbody Implant, China, suppliers, manufacturers, factory, wholesale, buy, price, for sale, made in China

Send Inquiry